Accepted answer
Thermal history during shipping is different for every vial, so a lot that experienced thermal abuse may have internal variation even if it was originally homogeneous.
If the lot was manufactured in multiple batches, testing vials from each batch separately establishes whether batch-to-batch variation is acceptable.
What each test answers
| Test | Answers | Does NOT answer |
|---|
| RP-HPLC, area % | What fraction of detected material is the target | How much target is present |
| Quantified content | Milligrams of peptide per vial | What the impurities are |
| ESI-MS identity | Whether the molecular weight matches | Purity, or isomeric substitution |
| Peptide mapping | Sequence, localised to a fragment | Quantity |
| Karl Fischer | Water content of the solid | Solvent content |
| LAL endotoxin | Pyrogen load in EU/mg | Sterility |
| Sterility test | Growth in defined media over 14 days | Endotoxin, or bioburden count |
Mechanically, if the entire lot failed qualification, a retest on a different vial is sometimes done, but reporting a retest result under the same lot number is misleading.
Published data on lot homogeneity from manufacturers who sample multiple vials consistently find variation below the published specifications, suggesting the sampling plans work.
If testing multiple vials, state how many you tested and why you chose those vials.
edited 1 Aug 2026 by Dr_Rosalind_Achebe — clarified the distinction between purity and content
3The timing signature is the useful part. Everything else is confounded. – h_pergande 9 months ago add a comment