For reference: SURMOUNT-1 · survodutide.

I want to understand what this actually establishes, as opposed to what it is being used to imply.

My concern is that I am being invited to draw a conclusion the data does not support.

Which parts of this are informative and which are decoration?

clinical-trials
clinical-trials

Reading the primary literature properly: estimands, intention-to-treat versus per-protocol, confidence intervals, absolute versus relative…

913 questions
semaglutide
semaglutide

A GLP-1 receptor agonist with a fatty-acid-acylated backbone and a roughly one-week half-life, marketed for type 2 diabetes and for weight…

360 questions
cardiovascular
cardiovascular

Cardiovascular outcomes: the SELECT major-adverse-event result, SOUL, SUSTAIN 6 and REWIND, how to convert a hazard ratio into an absolute risk…

111 questions
ecnoglutide
ecnoglutide

A long-acting GLP-1 receptor agonist with a cAMP-biased signalling profile. A niche tag, mostly used for mechanism questions about biased agonism…

14 questions
shareeditfollowflag
HV
askedh_villanueva50k3811 Mar 2026
6The arithmetic checks out. I ran the same numbers and got the same result. – lane_transit 10 months ago
add a comment

4 Answers

Accepted answer first, then by votes
48

Accepted answer

The underlying point is that start with the population. The inclusion criteria of the trial determine what its result can be extrapolated to, and the extrapolation people want is usually to a population the trial excluded.

Absolute risk reduction, worked: if the control-arm event rate is 8.0 per cent over the follow-up period and the hazard ratio is 0.80, the treated rate is approximately 6.4 per cent, the absolute risk reduction is 1.6 percentage points, and the number needed to treat is 1 ÷ 0.016 ≈ 63 over that period. A 20 per cent relative reduction and a number needed to treat of 63 are the same finding stated two ways, and only one of them sounds impressive.

Relative to absolute, worked

QuantityValueDerivation
Control-arm event rate8.0 %From the trial table, not the abstract
Hazard ratio0.80Reported
Treated event rate6.4 %8.0 × 0.80
Absolute risk reduction1.6 pp8.0 − 6.4
Number needed to treat631 ÷ 0.016
Relative risk reduction20 %1 − 0.80

The last two rows describe the same finding. Only one of them is used in headlines.

In practice, the rodent thyroid C-cell findings that generated the labelled warning appear to be species-specific: rodent C-cells express GLP-1 receptors at high density, human C-cells at very low density, and human calcitonin data across large trial populations has not reproduced the signal. A family history of medullary thyroid carcinoma or MEN2 is nonetheless a genuine contraindication rather than a theoretical one.

SELECT reported a hazard ratio of 0.80 (95% CI 0.72–0.90) for the primary composite major adverse cardiovascular event endpoint with semaglutide 2.4 mg in overweight or obese adults with established cardiovascular disease and without diabetes[1].

Read the confidence interval, read the estimand, and compute the absolute effect yourself. It takes two minutes and it changes how the result feels.

shareimprove this answerflag
TO
answered · acceptedt_oyelaran41k3824 May 2026
Related: the same reasoning applies to the counter-ion question. – mala_venkatesh 3 months ago
add a comment
Sponsored

PeptideMeter - Independent Peptide Analytics

Aggregated, published test results and vendor ratings built from submitted batches. Methodology stated, dataset browsable, no listing fees.

Browse results
56

In practice, this is a question about what the trial was designed to answer, and the honest response is that it was not designed to answer this.

The early fall in estimated glomerular filtration rate on treatment is haemodynamic rather than structural. Reduced intraglomerular pressure lowers the filtration rate acutely and preserves the glomerulus chronically — the same pattern seen with renin-angiotensin blockade and with SGLT2 inhibition. A dip of a few millilitres per minute in the first weeks, followed by a shallower long-term slope, is the desired trajectory, not a warning sign.

Estimated average glucose from HbA1c: eAG in mg/dL = 28.7 × A1c − 46.7, or in mmol/L, 1.59 × A1c − 2.59. An A1c of 6.5 per cent is therefore about 140 mg/dL or 7.8 mmol/L. The relationship is a population regression, so an individual can sit well off the line.

SUSTAIN 6 was the original cardiovascular outcomes trial for semaglutide in type 2 diabetes and is the reference point for the class effect that SELECT later extended to a non-diabetic population[1].

Convert everything to an absolute effect before you compare two interventions. Relative effects are not comparable across different baseline risks.

edited 22 Jun 2026 by orla_ferriter — reworded for clarity after a comment

shareimprove this answerflag
OF
answeredorla_ferriter47k3816 Jun 2026
1

Concretely, read the estimand before the effect size. Almost every apparent contradiction between two published figures from the same trial resolves once you notice that one is a trial-product estimand and the other is a treatment-policy estimand.

Liver enzymes are a poor surrogate for hepatic histology in both directions: substantial steatohepatitis with normal transaminases is common, and modest enzyme elevation with minimal fibrosis is common. If the question is fibrosis, the answer comes from a non-invasive score such as FIB-4 or a stiffness measurement, not from ALT.

To be exact about it, a network meta-analysis can rank agents that were never compared directly, but only under a transitivity assumption — that the trials being linked are similar enough in population, duration and endpoint definition for the indirect comparison to hold. In this field that assumption is often visibly violated, which is why indirect rankings should be read as hypotheses.

SURMOUNT-OSA reported reductions in the apnoea-hypopnoea index with tirzepatide in adults with obesity and moderate-to-severe obstructive sleep apnoea, both with and without concurrent positive airway pressure therapy[1].

None of this replaces a clinician who can see the whole picture, and the whole picture is usually where the answer is.

shareimprove this answerflag
VR
answeredv_ramaswamy40k385 Jun 2026
8I tested this on two lots and got the same answer, so at least it reproduces. – seven_day_half 7 months ago
The timing signature is the useful part. Everything else is confounded. – ilaria_bertone 9 months ago
add a comment
-2

The hazard ratio is the relative effect. What changes decisions is the absolute effect, and converting between them requires the event rate in the control arm, which is usually in the same table and rarely in the abstract.

Creatinine is a muscle-derived metabolite, so a substantial loss of lean mass lowers serum creatinine and mathematically raises estimated GFR without anything happening to the kidney. If you have lost twenty kilograms, your creatinine-based eGFR is flattering you. Cystatin C is not muscle-dependent and is the measure to use when the two disagree.

SURMOUNT-4 randomised participants after an open-label lead-in to continued tirzepatide or placebo, and the withdrawal arm regained a substantial proportion of the lost weight over the following year[1].

If the trend across three draws is flat, the difference between draws one and two was noise. Most of what people react to is noise.

shareimprove this answerflag
VV
answeredvoid_volume13k1613 May 2026
2This should probably be in the site help pages rather than buried in an answer. – halvard_ness 3 months ago
Good answer, but the confidence interval in the cited trial is wider than implied. – felix_araya 44 days ago