Why would Janoshik report 95.2% where the supplier certificate says something higher?

Asked 29 Jul 2025Modified 9 months agoViewed 30k times
26

Setup, so nobody has to ask: Janoshik · 95.2%.

This is not behaving the way I expected and I want to understand the discrepancy before I act on it.

I have photographed the current state and recorded the conditions, so I can answer follow-up questions precisely.

How do I distinguish the benign explanation from the one that matters?

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
shareeditfollowflag
TR
askedtobias_reint19k2729 Jul 2025
7Small correction: the units in the third paragraph should be micrograms, not milligrams. – Dr_Marek_Zielinski 9 months ago
6Do you have a reference for the last claim? Not disputing it, just want to read it. – Dr_Ingrid_Baumgartner 7 months ago
add a comment

5 Answers

Sorted by votes
51

On the detail: understanding purity requires separating the chemistry from the method from the reporting convention, and the three are not independent.

Column pore size affects mass transfer — a 100 Angstrom packing on a 5 kDa peptide restricts diffusion, broadening the peak and potentially hiding small impurities in the shoulders.

What each test answers

TestAnswersDoes NOT answer
RP-HPLC, area %What fraction of detected material is the targetHow much target is present
Quantified contentMilligrams of peptide per vialWhat the impurities are
ESI-MS identityWhether the molecular weight matchesPurity, or isomeric substitution
Peptide mappingSequence, localised to a fragmentQuantity
Karl FischerWater content of the solidSolvent content
LAL endotoxinPyrogen load in EU/mgSterility
Sterility testGrowth in defined media over 14 daysEndotoxin, or bioburden count

Mechanically, retention time is sequence-specific and method-specific, so comparing your result to a supplier value using a different method is meaningless without method documentation.

I would be careful about over-reading a single measurement — treat it as a data point, not as ground truth.

Compare purity within a single laboratory on the same method, never across laboratories.

shareimprove this answerflag
DB
answeredDr_Signe_Baldursdottir46k3814 Sept 2025
Sponsored

Sigma-Aldrich - Certified Reference Materials

Analytical standards and reagents with traceable certificates. Every quantitative result you read inherits the accuracy of the standard behind it.

Shop standards
33

It helps to be literal here: the honest answer is that the achievable range of plausible purity figures for a given vial is wider than most people expect.

Temperature affects the dynamics of molecular conformation, and if a peptide has proline residues that interconvert on the chromatographic timescale, the peak will split or shoulder at low temperature and collapse at high temperature.

Integration of the shoulder — whether you use perpendicular drop or tangent skim — determines what area gets assigned to the main peak versus the impurity table.

The caveat is that purity without identity is only half an answer — a high purity does not mean the peak is actually what you think it is.

If you are ranking vendors, specify a method and have all samples tested at the same place.

shareimprove this answerflag
M4
answeredmz_411399k25825 Sept 2025
27

Gradient slope is the most powerful parameter and almost nobody mentions it, which is why two reports on the same material disagree by a point.

Gradient slope controls resolution, and gentler slopes resolve co-eluting impurities into separate peaks — so the better method reports the worse purity number.

The underlying point is that sample solvent strength affects peak shape — if you inject in strong solvent on a gradient starting in weak solvent, the solvent peak can distort your main peak or create a false shoulder.

The limitation is that single-digit micro-impurities become invisible at typical reporting thresholds, so "no impurities detected" means "none above one in two thousand."

The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.

shareimprove this answerflag
DF
answeredDr_Nadia_Farsi90k2586 Oct 2025
21

Purity is a method-dependent figure, and that is not a limitation of the measurement, it is a property of what the measurement actually answers.

The fraction of your main peak that is actually your target versus isomers, fragments or related sequences is invisible without complementary identity testing.

The ICH Q3A impurity thresholds and the relevant pharmacopoeial chapters all specify method validation requirements that almost no research-grade certificate claims to meet.

Compare purity within a single laboratory on the same method, never across laboratories.

edited 21 Oct 2025 by zeynep_arslan — reworded for clarity after a comment

shareimprove this answerflag
ZA
answeredzeynep_arslan20k2817 Oct 2025
2Worth adding that the method section is where the answer usually is. – claudia_ferrante 9 months ago
add a comment
16

The part that matters: the short answer is that two competent laboratories on identical material will disagree, and the disagreement is almost always explainable by method differences.

Tailing factor measures peak shape, and a badly tailing peak spreads into the region where small impurities live, forcing tangent-skim integration that assigns tail area to the main peak.

If you are ranking vendors, specify a method and have all samples tested at the same place.

edited 5 Nov 2025 by bridget_nyathi — added the citation requested in comments

shareimprove this answerflag
BN
answeredbridget_nyathi16k1729 Oct 2025
2This is the answer I was looking for three months ago. – bea_forsberg 10 months ago
The arithmetic checks out. I ran the same numbers and got the same result. – Dr_Nadia_Farsi 8 months ago
add a comment