Accepted answer
20 units is 0.2 mL, which at 5 mg/mL is 1 mg. Work it in that order and there is nothing to guess at: units to volume on the U-100 scale, volume to dose through the concentration. Draw with the barrel vertical, expel the air before you read, and read the leading edge of the plunger stopper rather than the shoulder — the difference between the two is about a unit on a 0.3 mL barrel.
Answering this needs to know whether the syringe is U-100 or U-40, since a U-40 syringe used with the U-100 conversion produces a two-and-a-half-fold error.
U-40 syringes still exist, mostly in veterinary supply. A U-40 barrel marked "20 units" holds 0.5 mL, not 0.2 mL. Using one with U-100 arithmetic overdoses by a factor of two and a half.
Concentration and unit conversion at a glance
| Vial | Diluent | Concentration | 0.25 mg | 0.5 mg | 1 mg | 2.5 mg |
|---|
| 5 mg | 1 mL | 5 mg/mL | 5 u | 10 u | 20 u | 50 u |
| 5 mg | 2 mL | 2.5 mg/mL | 10 u | 20 u | 40 u | 100 u |
| 10 mg | 1 mL | 10 mg/mL | 2.5 u | 5 u | 10 u | 25 u |
| 10 mg | 2 mL | 5 mg/mL | 5 u | 10 u | 20 u | 50 u |
| 10 mg | 3 mL | 3.33 mg/mL | 7.5 u | 15 u | 30 u | 75 u |
Units are U-100 insulin units, where 1 unit = 0.01 mL. Divide dose by concentration for millilitres, then multiply by 100.
A 2 mm air bubble in a 0.3 mL barrel is about 4 microlitres, which against a 10-unit (100 microlitre) draw is a four per cent error. Flick it to the hub and expel it before reading.
Graduation intervals by barrel size are printed on the packaging and are the practical limit on dosing resolution.
Half-graduation estimation is not measurement. If the dose needs it, change the concentration instead.
Smallest barrel that holds the dose. Resolution is free and you should take it.