Accepted answer
Start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.
For the solid state, residual moisture is the dominant variable. A cake at two per cent water is considerably more stable than the same cake at six per cent, because water is both a reactant in hydrolysis and a plasticiser that lowers the glass transition temperature. This is why a desiccant in the outer packaging is not theatre, and why opening a cold vial in a humid room is a genuine error — you condense water onto the cake.
Reported and extrapolated stability by condition
| State | Condition | Usable window | Basis |
|---|
| Lyophilised solid | −20 °C, sealed, dry | 24–36 months | Supplier guidance |
| Lyophilised solid | 2–8 °C, sealed | 12–24 months | Supplier guidance |
| Lyophilised solid | 25 °C, sealed | 4–8 weeks | Extrapolated (Arrhenius) |
| Lyophilised solid | 40 °C, sealed | 1–2 weeks | Extrapolated |
| Solution, preserved | 2–8 °C | 28 days | USP microbiological convention |
| Solution, preserved | 25 °C | 3–7 days | Extrapolated |
| Solution, unpreserved | 2–8 °C | 24 hours | USP microbiological convention |
Windows for the solid state are chemical; windows for solution are microbiological and usually shorter than the chemical limit.
Adsorption to the container is a real loss at low concentration. For a peptide at 0.1 mg/mL in an untreated glass vial, single-digit percentage losses to the wall are plausible; at 5 mg/mL it is negligible. This is one of several reasons not to reconstitute to a very dilute working solution and store it.
General guidance on lyophilised peptide storage from the major synthesis houses converges on minus twenty degrees for long-term storage of solids and refrigerated storage for solutions in use, with the explicit note that repeated freeze-thaw of solutions should be avoided. It is consistent advice precisely because it follows from the chemistry rather than from a study.
The limitation is that you cannot detect slow aggregation by eye until it is well advanced, so a clear vial is weak evidence of an intact one.
If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.