Freeze-thaw damage happens at the moving ice front, not at the storage temperature. Once the sample is frozen solid and cold, very little is happening. The damage is done during freezing and thawing, which is why the number of cycles matters and the duration of the hold mostly does not.
A domestic freezer holds roughly minus eighteen degrees and cycles by several degrees on its defrost schedule, which for a lyophilised solid is entirely adequate and for a frozen solution means repeated partial melting at the surface. If you are going to freeze a solution, an unopened chest freezer is materially better than the compartment in the top of a fridge.
Stated carefully, aggregation is the failure mode that reverse-phase HPLC is worst at detecting, because a large soluble aggregate may not elute at all and an insoluble one is filtered out during sample preparation. If your purity result comes back normal but the vial looks hazy, believe the vial. Size-exclusion chromatography is the method that sees this.
General guidance on lyophilised peptide storage from the major synthesis houses converges on minus twenty degrees for long-term storage of solids and refrigerated storage for solutions in use, with the explicit note that repeated freeze-thaw of solutions should be avoided. It is consistent advice precisely because it follows from the chemistry rather than from a study.
Worth stating: research-use-only material has no stability programme behind it at all, so any beyond-use date you apply is your own construct.
The practical rule is that time and temperature multiply, so shorten whichever one you control.