My liraglutide vial sat at 37 °C for fourteen days — is testing worth it before use?

Asked 16 Aug 2024Modified 21 months agoViewed 20k times
17

For reference: liraglutide · 37 °C · fourteen days.

I am at the decision point and I would rather think it through than improvise.

I would rather spend money on measurement than on redundancy.

How do I make this decision on evidence rather than on feel?

cold-chain
cold-chain

Keeping material within a temperature window from manufacture to use: phase-change packs versus dry ice, thermal mass, transit-lane temperature…

524 questions
peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
shareeditfollowflag
FU
askedforty_units14k1716 Aug 2024

4 Answers

Accepted answer first, then by votes
71

Accepted answer

Mechanically, a warm arrival is a reason to test, not automatically a reason to discard. Peptide degradation is kinetic — rate multiplied by time — and a few days at thirty degrees in the solid state is a small integral compared to weeks in solution.

A domestic freezer holds roughly minus eighteen degrees and cycles by several degrees on its defrost schedule, which for a lyophilised solid is entirely adequate and for a frozen solution means repeated partial melting at the surface. If you are going to freeze a solution, an unopened chest freezer is materially better than the compartment in the top of a fridge.

On the detail: practical thermal arithmetic for a shipment: a single 250 g phase-change pack in a thin-walled polystyrene box holds sub-ten-degrees for roughly 24 to 48 hours in a 25 °C ambient, and considerably less at 35 °C. Any lane taking eight to fourteen days is therefore not temperature-controlled for most of its duration regardless of what was in the box, which is the argument for shipping the material lyophilised.

Deamidation kinetics for asparagine in peptides are well characterised and strongly sequence-dependent: the residue following the asparagine dominates the rate, with glycine and serine at the n+1 position accelerating it by an order of magnitude relative to bulkier residues. That is why two peptides in the same buffer at the same temperature can have quite different shelf lives.

The caveat is that "within specification" and "unchanged" are different claims. A vial can lose a few per cent of content and still be usable for its purpose while no longer matching its certificate.

Store solid, store cold, store dry, and reconstitute what you will use rather than what fits in the vial.

shareimprove this answerflag
RI
answered · acceptedrukhsana_iqbal14k287 Oct 2024
2The placebo-arm figure is the part everyone omits. – a_lindgren 6 months ago
add a comment
Sponsored

Sigma-Aldrich - Certified Reference Materials

Analytical standards and reagents with traceable certificates. Every quantitative result you read inherits the accuracy of the standard behind it.

Shop standards
85

Start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.

Light matters for specific residues rather than in general. Tryptophan and to a lesser extent tyrosine and methionine are photo-labile; a sequence without them is largely indifferent to ambient light over the timescales in question. Amber glass is cheap insurance rather than a requirement.

The 28-day figure for a reconstituted preserved vial is microbiological, not chemical. Chemically, a well-behaved peptide at 5 mg/mL at 4 °C will typically lose well under a per cent of content per month. The reason to respect the date is bioburden, and bioburden is a function of how many times you have opened it, not of the calendar.

I would be careful about generalising across sequences. Stability is sequence-specific, and a rule derived from semaglutide will not transfer cleanly to a tri-agonist with different residues in different local environments.

If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.

shareimprove this answerflag
DC
answeredDr_Idris_Coulibaly40k13829 Oct 2024
3The distinction between purity and content cannot be repeated often enough here. – Dr_Ilse_Vandenberg 34 days ago
add a comment
58

It helps to be literal here: degradation is not one process, and which one dominates depends on the condition you are asking about. In solution at refrigerated temperature the rate-limiting pathway is usually deamidation and hydrolysis; at room temperature aggregation overtakes them; frozen, the damage happens during the transitions rather than during the hold.

Adsorption to the container is a real loss at low concentration. For a peptide at 0.1 mg/mL in an untreated glass vial, single-digit percentage losses to the wall are plausible; at 5 mg/mL it is negligible. This is one of several reasons not to reconstitute to a very dilute working solution and store it.

Stated carefully, freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.

The Arrhenius relationship underpinning accelerated stability testing is the basis of ICH Q1A, which is why accelerated studies at 40 °C and 75 per cent relative humidity are used to predict shelf life at 25 °C. The same relationship lets you reason about a warm transit lane, with the same caveats about extrapolation.

Minimise transitions rather than minimising temperature. One freeze and one thaw is fine; five is a different question.

edited 29 Oct 2024 by Dr_Ilse_Vandenberg — added the method parameters

shareimprove this answerflag
DV
answeredDr_Ilse_Vandenberg78k24818 Oct 2024
8I would gently push back on the second point — the evidence there is thinner than stated. – Dr_Nadia_Farsi 10 months ago
7Adding for future readers: the certificate should carry the lot number, not just a batch code. – rhian_prydderch 8 months ago
add a comment
34

The lyophilised solid is far more robust than anything anyone says about it, and the solution is far less robust. Most of the confusion in this area comes from advice about one being applied to the other.

The temperature dependence is roughly Arrhenius over the range that matters, which in practice means every ten degrees of increase roughly doubles to triples the rate. Ten days at thirty degrees is therefore comparable to something on the order of a month or two at four degrees — bad, but not the catastrophe it feels like when you open a warm parcel.

Where community-submitted samples with known thermal excursions have been tested at Janoshik or Medutest, the recurring finding is that lyophilised material tolerates warm transit far better than intuition suggests, while reconstituted material shipped warm does not. The asymmetry is consistent enough to plan around.

The limitation is that you cannot detect slow aggregation by eye until it is well advanced, so a clear vial is weak evidence of an intact one.

The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.