Freeze-thaw damage happens at the moving ice front, not at the storage temperature. Once the sample is frozen solid and cold, very little is happening. The damage is done during freezing and thawing, which is why the number of cycles matters and the duration of the hold mostly does not.
Freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.
On re-freezing something that thawed in transit: if it arrived as a lyophilised solid that warmed but never got wet, re-freezing costs you nothing except the thermal cycle. If it arrived as a solution that thawed, re-freezing adds a second transition and therefore a second dose of ice-front shear. The asymmetry is worth internalising.
The Arrhenius relationship underpinning accelerated stability testing is the basis of ICH Q1A, which is why accelerated studies at 40 °C and 75 per cent relative humidity are used to predict shelf life at 25 °C. The same relationship lets you reason about a warm transit lane, with the same caveats about extrapolation.
The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.