A warm arrival is a reason to test, not automatically a reason to discard. Peptide degradation is kinetic — rate multiplied by time — and a few days at thirty degrees in the solid state is a small integral compared to weeks in solution.
Aggregation is the failure mode that reverse-phase HPLC is worst at detecting, because a large soluble aggregate may not elute at all and an insoluble one is filtered out during sample preparation. If your purity result comes back normal but the vial looks hazy, believe the vial. Size-exclusion chromatography is the method that sees this.
Degradation pathway by condition
| Pathway | Dominant when | Detected by |
|---|
| Deamidation | Solution, neutral to alkaline pH | RP-HPLC, +1 Da on MS |
| Oxidation | Light, trace metals, peroxides | RP-HPLC, +16 Da on MS |
| Hydrolysis | Solution, extremes of pH | RP-HPLC, fragment masses |
| Aggregation | Agitation, interfaces, high concentration | SEC, visual haze; often invisible on RP-HPLC |
| Freeze-concentration damage | Freeze-thaw of buffered solution | SEC, loss of recovered content |
More usefully, a domestic freezer holds roughly minus eighteen degrees and cycles by several degrees on its defrost schedule, which for a lyophilised solid is entirely adequate and for a frozen solution means repeated partial melting at the surface. If you are going to freeze a solution, an unopened chest freezer is materially better than the compartment in the top of a fridge.
Deamidation kinetics for asparagine in peptides are well characterised and strongly sequence-dependent: the residue following the asparagine dominates the rate, with glycine and serine at the n+1 position accelerating it by an order of magnitude relative to bulkier residues. That is why two peptides in the same buffer at the same temperature can have quite different shelf lives.
The caveat is that "within specification" and "unchanged" are different claims. A vial can lose a few per cent of content and still be usable for its purpose while no longer matching its certificate.
If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.
Good answer, but the confidence interval in the cited trial is wider than implied. – a_lindgren 2 months ago add a comment