It helps to be literal here: reporting threshold is convention and not chemistry, which is why two certificates with different thresholds disagree by a tenth of a point or more.
Column pore size affects mass transfer — a 100 Angstrom packing on a 5 kDa peptide restricts diffusion, broadening the peak and potentially hiding small impurities in the shoulders.
The fraction of your main peak that is actually your target versus isomers, fragments or related sequences is invisible without complementary identity testing.
The ICH Q3A impurity thresholds and the relevant pharmacopoeial chapters all specify method validation requirements that almost no research-grade certificate claims to meet.
The limitation is that single-digit micro-impurities become invisible at typical reporting thresholds, so "no impurities detected" means "none above one in two thousand."
The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.
3Worth adding that the method section is where the answer usually is. – shear_at_the_front 9 months ago add a comment