PeptideStack
5.2kquestions
20kanswers
220users

Is there any published stability data for liraglutide at minus 80 °C?

Asked 11 Oct 2024Modified 19 months agoViewed 8k times
6

For reference: liraglutide · minus 80 °C.

I would like to know whether this claim survives contact with evidence.

If the answer is "nobody has tested that", I would like that stated so I can stop looking.

Is this actually true, and what is the evidence?

peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
storage
storage

Storage conditions and their evidence base: minus twenty degrees for powder, refrigerated for solution, protection from light, and what the…

646 questions
clinical-trials
clinical-trials

Reading the primary literature properly: estimands, intention-to-treat versus per-protocol, confidence intervals, absolute versus relative…

913 questions
shareeditfollowflag
FF
askedfibre_or_fragment12k1811 Oct 2024
3Is there a reason to prefer the second method over the first, other than cost? – u100_marks 6 months ago
add a comment

5 Answers

Accepted answer first, then by votes
107

Accepted answer

A warm arrival is a reason to test, not automatically a reason to discard. Peptide degradation is kinetic — rate multiplied by time — and a few days at thirty degrees in the solid state is a small integral compared to weeks in solution.

Adsorption to the container is a real loss at low concentration. For a peptide at 0.1 mg/mL in an untreated glass vial, single-digit percentage losses to the wall are plausible; at 5 mg/mL it is negligible. This is one of several reasons not to reconstitute to a very dilute working solution and store it.

Degradation pathway by condition

PathwayDominant whenDetected by
DeamidationSolution, neutral to alkaline pHRP-HPLC, +1 Da on MS
OxidationLight, trace metals, peroxidesRP-HPLC, +16 Da on MS
HydrolysisSolution, extremes of pHRP-HPLC, fragment masses
AggregationAgitation, interfaces, high concentrationSEC, visual haze; often invisible on RP-HPLC
Freeze-concentration damageFreeze-thaw of buffered solutionSEC, loss of recovered content

Practical thermal arithmetic for a shipment: a single 250 g phase-change pack in a thin-walled polystyrene box holds sub-ten-degrees for roughly 24 to 48 hours in a 25 °C ambient, and considerably less at 35 °C. Any lane taking eight to fourteen days is therefore not temperature-controlled for most of its duration regardless of what was in the box, which is the argument for shipping the material lyophilised.

Deamidation kinetics for asparagine in peptides are well characterised and strongly sequence-dependent: the residue following the asparagine dominates the rate, with glycine and serine at the n+1 position accelerating it by an order of magnitude relative to bulkier residues. That is why two peptides in the same buffer at the same temperature can have quite different shelf lives.

The caveat is that "within specification" and "unchanged" are different claims. A vial can lose a few per cent of content and still be usable for its purpose while no longer matching its certificate.

Store solid, store cold, store dry, and reconstitute what you will use rather than what fits in the vial.

shareimprove this answerflag
BQ
answered · acceptedbounty_hunter_q18k2815 Dec 2024
7Do you have a reference for the last claim? Not disputing it, just want to read it. – tandem_gradient 7 months ago
add a comment
Sponsored

Sigma-Aldrich - Certified Reference Materials

Analytical standards and reagents with traceable certificates. Every quantitative result you read inherits the accuracy of the standard behind it.

Shop standards
43

On the detail: freeze-thaw damage happens at the moving ice front, not at the storage temperature. Once the sample is frozen solid and cold, very little is happening. The damage is done during freezing and thawing, which is why the number of cycles matters and the duration of the hold mostly does not.

The temperature dependence is roughly Arrhenius over the range that matters, which in practice means every ten degrees of increase roughly doubles to triples the rate. Ten days at thirty degrees is therefore comparable to something on the order of a month or two at four degrees — bad, but not the catastrophe it feels like when you open a warm parcel.

The 28-day figure for a reconstituted preserved vial is microbiological, not chemical. Chemically, a well-behaved peptide at 5 mg/mL at 4 °C will typically lose well under a per cent of content per month. The reason to respect the date is bioburden, and bioburden is a function of how many times you have opened it, not of the calendar.

General guidance on lyophilised peptide storage from the major synthesis houses converges on minus twenty degrees for long-term storage of solids and refrigerated storage for solutions in use, with the explicit note that repeated freeze-thaw of solutions should be avoided. It is consistent advice precisely because it follows from the chemistry rather than from a study.

I would be careful about generalising across sequences. Stability is sequence-specific, and a rule derived from semaglutide will not transfer cleanly to a tri-agonist with different residues in different local environments.

Minimise transitions rather than minimising temperature. One freeze and one thaw is fine; five is a different question.

shareimprove this answerflag
SC
answeredstopper_core50k1384 Dec 2024
2I would gently push back on the second point — the evidence there is thinner than stated. – jonas_ekstrom 9 months ago
Adding for future readers: the certificate should carry the lot number, not just a batch code. – ines_brandt 7 months ago
add a comment
30

The underlying point is that degradation is not one process, and which one dominates depends on the condition you are asking about. In solution at refrigerated temperature the rate-limiting pathway is usually deamidation and hydrolysis; at room temperature aggregation overtakes them; frozen, the damage happens during the transitions rather than during the hold.

Light matters for specific residues rather than in general. Tryptophan and to a lesser extent tyrosine and methionine are photo-labile; a sequence without them is largely indifferent to ambient light over the timescales in question. Amber glass is cheap insurance rather than a requirement.

To be exact about it, freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.

One qualification: none of this addresses sterility. A vial can be chemically pristine and microbiologically compromised, and a chromatogram will not tell you which.

The practical rule is that time and temperature multiply, so shorten whichever one you control.

shareimprove this answerflag
IB
answeredines_brandt93k24823 Nov 2024
8Is there a reason to prefer the second method over the first, other than cost? – marta_okonkwo 2 months ago
add a comment
25

The lyophilised solid is far more robust than anything anyone says about it, and the solution is far less robust. Most of the confusion in this area comes from advice about one being applied to the other.

Aggregation is the failure mode that reverse-phase HPLC is worst at detecting, because a large soluble aggregate may not elute at all and an insoluble one is filtered out during sample preparation. If your purity result comes back normal but the vial looks hazy, believe the vial. Size-exclusion chromatography is the method that sees this.

Where community-submitted samples with known thermal excursions have been tested at Janoshik or Medutest, the recurring finding is that lyophilised material tolerates warm transit far better than intuition suggests, while reconstituted material shipped warm does not. The asymmetry is consistent enough to plan around.

The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.

shareimprove this answerflag
EV
answeredesther_vandeVelde49k3812 Nov 2024
24

Start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.

A domestic freezer holds roughly minus eighteen degrees and cycles by several degrees on its defrost schedule, which for a lyophilised solid is entirely adequate and for a frozen solution means repeated partial melting at the surface. If you are going to freeze a solution, an unopened chest freezer is materially better than the compartment in the top of a fridge.

The licensed semaglutide and tirzepatide presentations carry in-use periods of several weeks at room temperature in their labelling, which is the closest thing to real stability data in this space — and it applies to a buffered, surfactant-containing, preservative-containing formulation, not to a reconstituted research vial.

If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.

edited 12 Nov 2024 by bufferline42 — added the placebo-arm figures

shareimprove this answerflag
BU
answeredbufferline4249k1381 Nov 2024

Your answer

Ask PeptideStack is a static archive. Posting is closed, but the norms are worth stating: answer the question that was asked, show your working, cite the trial or the certificate, and say plainly where the evidence runs out.

Not medical advice. Research-use-only compounds are not approved for human use.