Accepted answer
It gives 10 mg/mL, and whether that is sensible depends on the dose you will draw from it. 10 ÷ 1 = 10 mg/mL in 0.9% sodium chloride. A 0.5 mg dose is then 5 units on a U-100 barrel and a 1 mg dose is 10 units. Both land in a readable part of the barrel, which is the whole point of choosing the volume deliberately.
Answering this needs the syringe you actually own, because the barrel graduations decide what "readable" means.
The other direction: 10 mg in 3 mL is 3.33 mg/mL, and a 0.5 mg dose becomes 0.15 mL, or 15 units. More barrel, easier reading, and a larger fraction of the vial volume lost to dead space across the same number of draws.
Dead space by syringe type
| Configuration | Dead volume | Loss at 5 mg/mL | Over 20 draws |
|---|
| Fixed-needle insulin syringe | 3–5 µL | 15–25 µg | 0.3–0.5 mg |
| Low-dead-space, detachable | <2 µL | <10 µg | <0.2 mg |
| Standard luer-lock + 30G | 35–60 µL | 175–300 µg | 3.5–6 mg |
| Luer-lock + 21G drawing needle | 70–100 µL | 350–500 µg | 7–10 mg |
Mechanically, vial headspace is the hard constraint. A nominal 2 mL vial typically holds a little over 2 mL to the shoulder; adding 3 mL is not an option and attempting it wastes the lot.
Nominal vial volumes in the standard 2R and 3R glass sizes have published brimful capacities well above the nominal fill, but the usable volume is bounded by the stopper displacement.
Concentration equals content over volume, and content is not label claim.
Small correction: the units in the third paragraph should be micrograms, not milligrams. – e_dziedzic 7 months ago Does this change at lower concentrations, or does adsorption start to dominate? – Dr_Jonas_Halvorsen 5 months ago add a comment