Accepted answer
100 units. Volume first: 5 mg ÷ 5 mg/mL = 1 mL. On a 1 mL luer-lock syringe one unit is 0.01 mL, so 1 ÷ 0.01 = 100 units. It lands on a whole graduation, which is what you want from a reconstitution volume.
Work in the order concentration, then volume, then units, and the arithmetic stops being confusing. Concentration is milligrams per millilitre and comes from the vial contents and the diluent volume. Volume per dose is dose divided by concentration. Units on a U-100 syringe are volume in millilitres multiplied by one hundred.
The rounding error accumulates if you round too many times — rounding concentration to 5.0, rounding the dose volume to 0.1 mL, rounding the unit reading to 10 — and the safest approach is to work the full precision and round only the final answer.
Dead space by syringe type
| Configuration | Dead volume | Loss at 5 mg/mL | Over 20 draws |
|---|
| Fixed-needle insulin syringe | 3–5 µL | 15–25 µg | 0.3–0.5 mg |
| Low-dead-space, detachable | <2 µL | <10 µg | <0.2 mg |
| Standard luer-lock + 30G | 35–60 µL | 175–300 µg | 3.5–6 mg |
| Luer-lock + 21G drawing needle | 70–100 µL | 350–500 µg | 7–10 mg |
Dead space quantified: a fixed-needle insulin syringe holds roughly 3 to 5 µL in the hub and needle after the plunger bottoms out. A luer-lock syringe with a detachable needle holds 35 to 100 µL depending on the hub design. At 5 mg/mL that is 15 to 25 µg lost per draw on the insulin syringe and 175 to 500 µg on the luer-lock — which over ten draws is the difference between losing a rounding error and losing half a milligram.
The Arrhenius relationship for drawing kinetics means that cold solution takes noticeably longer to draw than room-temperature solution.
If in doubt, use more diluent and accept the shorter usable window.
4Would this be different for a peptide that foams? Mine does and I have never known why. – Dr_Signe_Baldursdottir 9 months ago add a comment