Accepted answer
Whatever the refrigerated figure is, divide it by about 3.4. Room temperature is not a number, so take the pharmacopoeial 20–25 °C and its 22.5 °C midpoint: 17.5 kelvin above the 5 °C middle of a 2–8 °C refrigerator. The ten-degree rule of thumb — degradation rate roughly doubling per 10 K — puts that at about 3.4 times the refrigerated rate. It is an order-of-magnitude statement about a rate, not a shelf life, and the top of the 20–25 °C band runs about 1.4 times faster than the bottom of it. So a preparation with a twenty-eight day refrigerated figure has roughly 8 days at room temperature on the same assumption — an order-of-magnitude answer, not a shelf life, and it says nothing about sterility, which has its own clock. "Within specification" also needs a specification: purity, content, or both, and at what limit. Without that the question has no numerical answer at all.
Answering this needs the physical state, since a dry powder is protected from most of these and a solution is protected from none.
Light exposure matters for tryptophan-containing sequences and for anything with a chromophore. Amber vials and a closed box are free mitigations.
Reported and extrapolated stability by condition
| State | Condition | Usable window | Basis |
|---|
| Lyophilised solid | −20 °C, sealed, dry | 24–36 months | Supplier guidance |
| Lyophilised solid | 2–8 °C, sealed | 12–24 months | Supplier guidance |
| Lyophilised solid | 25 °C, sealed | 4–8 weeks | Extrapolated (Arrhenius) |
| Lyophilised solid | 40 °C, sealed | 1–2 weeks | Extrapolated |
| Solution, preserved | 2–8 °C | 28 days | USP microbiological convention |
| Solution, preserved | 25 °C | 3–7 days | Extrapolated |
| Solution, unpreserved | 2–8 °C | 24 hours | USP microbiological convention |
Windows for the solid state are chemical; windows for solution are microbiological and usually shorter than the chemical limit.
Aggregation is physical: peptides unfold at air-liquid interfaces and associate. Shaking maximises that interface, which is why swirling and shaking produce visibly different outcomes on the same vial.
Adsorption losses at low concentrations are quantified in formulation studies and are the reason carrier proteins are used in dilute preparations.
Nothing here is medical advice, and research-use compounds are not approved for human use.
Swirl, never shake. Aggregation is a handling problem more than a time problem.