PeptideStack
5.2kquestions
20kanswers
220users

purity

Page 30 of 33 · 788 questions tagged purity.

788 questions · sorted by votes · page 30 of 33

6 votes0 answers2k views
Is a 98.8% result from Medutest comparable to 99.4% from PeptideMeter?

Setup, so nobody has to ask: 98.8% · Medutest · 99.4% · PeptideMeter. Both of these get recommended confidently by different people, which suggests neither is…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by zainab_mustafa 16k · 10 months ago
5 votes 5 answers23k views
How does survodutide behave on a C4 column compared to semaglutide?

The case in front of me: survodutide · a C4 column · semaglutide. I would like the axes of comparison first and the recommendation second. I have tried the first…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by nynke_dekker 18k · 2.0 years ago
5 votes 5 answers23k views
Would you accept 98.8% on tirzepatide from WXT without a content assay?

Conditions: 98.8% · tirzepatide · WXT. The failure mode I am trying to avoid is making this decision emotionally. I have twelve months in view and I would like the…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
vendor-vetting
vendor-vetting

Evaluating a supplier on evidence rather than reputation: testing history across batches, whether certificates are batch-specific, how failures…

436 questions
asked by bea_forsberg 14k · 2.1 years ago
5 votes5 answers19k views
Is 99.4% a realistic purity ceiling for cagrilintide given its chain length?

Stated plainly: 99.4% · cagrilintide. The units are where I keep going wrong, so please be explicit about them. I have sanity-checked the order of magnitude and it…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
peptide-mapping
peptide-mapping

Enzymatic digestion followed by LC-MS/MS to confirm sequence rather than just mass. The method that catches a scrambled sequence or a D-amino-acid…

83 questions
asked by cal_hennessy 14k · 2.3 years ago
5 votes5 answers14k views
How does mazdutide behave on a C8 column compared to cagrilintide?

Numbers first: mazdutide · a C8 column · cagrilintide. I want to know what the trade-off actually is rather than which option is fashionable. I would rather have a…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by harriet_lonsdale 14k · 10 months ago
5 votes5 answers10k views
What does a 98.4% purity with a date of analysis attached let me conclude?

Concretely: 98.4% · date of analysis. I would like to know the limits of what can be inferred from this. What I am trying to avoid is over-reading a single result,…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
asked by tri_gly_ala 48k · 2.0 years ago
5 votes 5 answers9.1k views
How do I reconcile 98.8% from Janoshik with 96.4% from the supplier?

Numbers first: 98.8% · Janoshik · 96.4%. Before I write this off, I want to check whether it is a known failure mode. I have the lot number, the certificate and the…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
peptidemeter
peptidemeter

PeptideMeter, an independent peptide analytics and vendor-rating service. Use this tag for its published datasets, its rating methodology, and how…

14 questions
asked by jonas_ekstrom 18k · 9 months ago
5 votes5 answers9k views
How do I compute the +5 charge state m/z for a peptide of 4731.3 Da?

Concretely: +5 · 4731.3 Da. Please show the division. I want to check my own against yours. I would like the general form as well as the specific number, so I can…

mass-spec
mass-spec

Mass spectrometry for identity confirmation: electrospray ionisation, multiple charge states, monoisotopic versus average mass, deconvolution, and…

38 questions
dosing-math
dosing-math

The arithmetic itself: milligrams to millilitres to insulin units, concentration after reconstitution, dose per draw, and vial-days per vial. Show…

811 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
asked by ben_akintola 14k · 18 months ago
5 votes5 answers8.3k views
What counter-ion should I expect on a BCH a GLP-1 receptor agonist lot?

Stated plainly: BCH · a GLP-1 receptor agonist. I would like help reading this properly rather than being told what conclusion to reach. I have the full report…

acetate-content
acetate-content

Counter-ion content, most often acetate or trifluoroacetate, and why it matters: the counter-ion and residual water are part of the gross mass you…

87 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
asked by tenth_of_a_unit 40k · 2.1 years ago
5 votes4 answers7.9k views
Why do two laboratories report different purity for the same vial?

The lot number on the vial matches the certificate, which at least rules out the easy problem. I keep seeing this stated as a fact with no explanation attached, and…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by tobias_maartens 94k · 7 months ago
5 votes5 answers7.8k views
Does dimerisation produce a resolvable peak on a C18 column, or does it co-elute?

Setup, so nobody has to ask: dimerisation · a C18 column. The empirical answer seems settled. The explanation does not. If the honest answer is that nobody knows, I…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
asked by label_claim 11k · 5 months ago
5 votes3 answers7.6k views
Is a 97.9% result from VendorInvestigate comparable to 97.1% from Janoshik?

Conditions: 97.9% · VendorInvestigate · 97.1% · Janoshik. These are treated as interchangeable and I do not think they are. If both are acceptable I would like to…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by thermal_mass 16k · 22 months ago
5 votes 5 answers7.4k views
Is a 99.4% result from PeptideMeter comparable to 98.2% from Janoshik?

For reference: 99.4% · PeptideMeter · 98.2% · Janoshik. I am trying to choose between two options that are usually discussed as though only one exists. I am not…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by dana_wexler 15k · 11 months ago
5 votes 4 answers7k views
How do I read an impurity table on a dulaglutide certificate against the 98.8% headline?

Stated plainly: dulaglutide · 98.8%. The units are where I keep going wrong, so please be explicit about them. I have sanity-checked the order of magnitude and it…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
asked by Dr_Malik_Osei 37k · 7 months ago
5 votes 5 answers6k views
How do I reconcile 97.6% from Janoshik with 95.2% from the supplier?

Numbers first: 97.6% · Janoshik · 95.2%. Before I write this off, I want to check whether it is a known failure mode. I have the lot number, the certificate and the…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by area_percent 13k · 3 months ago
5 votes5 answers6k views
How do I read a tirzepatide chromatogram from PeptideMeter beyond the headline number?

The specifics, since they change the answer: tirzepatide · PeptideMeter. I want to understand what this actually establishes, as opposed to what it is being used to…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by petra_hovland 42k · 13 months ago
5 votes 2 answers4.9k views
Would you accept 99.1% on liraglutide from FGP without a content assay?

The case in front of me: 99.1% · liraglutide · FGP. I want to decide this in advance so that I am not deciding it under pressure later. Assume I will follow the plan…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
vendor-vetting
vendor-vetting

Evaluating a supplier on evidence rather than reputation: testing history across batches, whether certificates are batch-specific, how failures…

436 questions
asked by sample_id 17k · 6 months ago
5 votes0 answers3.2k views
Is 97.1% a realistic purity ceiling for tirzepatide given its chain length?

Conditions: 97.1% · tirzepatide. Please show the division. I want to check my own against yours. I would like the general form as well as the specific number, so I…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
peptide-mapping
peptide-mapping

Enzymatic digestion followed by LC-MS/MS to confirm sequence rather than just mass. The method that catches a scrambled sequence or a D-amino-acid…

83 questions
asked by rota_site 55k · 18 months ago
5 votes3 answers2.9k views
How do I compute the +3 charge state m/z for a peptide of 4207.2 Da?

Setup, so nobody has to ask: +3 · 4207.2 Da. The units are where I keep going wrong, so please be explicit about them. I have sanity-checked the order of magnitude…

mass-spec
mass-spec

Mass spectrometry for identity confirmation: electrospray ionisation, multiple charge states, monoisotopic versus average mass, deconvolution, and…

38 questions
dosing-math
dosing-math

The arithmetic itself: milligrams to millilitres to insulin units, concentration after reconstitution, dose per draw, and vial-days per vial. Show…

811 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
asked by pierce_count 15k · 6 months ago
5 votes0 answers1.9k views
How do I compute the +4 charge state m/z for a peptide of 4113.6 Da?

The particulars: +4 · 4113.6 Da. I would like the arithmetic checked rather than the conclusion asserted. I have deliberately not used an online calculator because I…

mass-spec
mass-spec

Mass spectrometry for identity confirmation: electrospray ionisation, multiple charge states, monoisotopic versus average mass, deconvolution, and…

38 questions
dosing-math
dosing-math

The arithmetic itself: milligrams to millilitres to insulin units, concentration after reconstitution, dose per draw, and vial-days per vial. Show…

811 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
asked by jonas_ekstrom 18k · 2 months ago
5 votes0 answers1.4k views
What does a 99.4% purity with a lot-specific certificate attached let me conclude?

Numbers first: 99.4% · lot-specific certificate. This is presented as though it settles something, and I am not convinced it does. I have two documents that appear to…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
asked by liam_bracken 12k · 8 months ago
4 votes 5 answers23k views
How does cagrilintide behave on a C8 column compared to retatrutide?

Details up front: cagrilintide · a C8 column · retatrutide. I want to know what the trade-off actually is rather than which option is fashionable. I would rather have…

hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

466 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

179 questions
asked by fiadh_cronin 14k · 22 months ago
4 votes 5 answers19k views
Does hydrolysis of dulaglutide at minus 20 °C show up as a loss of content or of purity?

Details up front: hydrolysis · dulaglutide · minus 20 °C. I suspect the usual explanation for this is wrong, or at least incomplete. I am aware this may have a boring…

peptide-stability
peptide-stability

The chemistry of peptide degradation: deamidation, oxidation, hydrolysis, aggregation and fibrillation, and how temperature, pH, ionic strength,…

832 questions
content-assay
content-assay

Quantified content: how many milligrams of peptide are actually in the vial, measured against a calibrated reference standard. A separate test…

438 questions
purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
asked by priya_menon 11k · 19 months ago
4 votes5 answers18k views
How do I reconcile 96.4% from PeptideMeter with 95.2% from the supplier?

The particulars: 96.4% · PeptideMeter · 95.2%. An unexpected observation, and I would like a differential rather than reassurance. The conditions were within what I…

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

788 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

865 questions
coa
coa

Certificates of analysis: what fields a useful one carries, how to tell a real analytical report from a marketing document, batch and lot…

749 questions
asked by mass_shift_18 14k · 2.0 years ago