PeptideStack
5.2kquestions
20kanswers
220users

Why would Janoshik report 98.4% where the supplier certificate says something higher?

Asked 10 Feb 2026Modified 31 days agoViewed 14k times
18

What I am working with: Janoshik · 98.4%.

I noticed this today and I have not touched anything since, in case the state is diagnostic.

I have not discarded anything yet, so a test is still possible if that is the recommendation.

Should I be treating this as a failure or as noise?

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
hplc
hplc

Reverse-phase high-performance liquid chromatography, the workhorse purity method. Column chemistry, mobile-phase choice, gradient slope,…

503 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
janoshik
janoshik

Janoshik Analytical, an independent third-party testing laboratory widely used by this community for HPLC purity, identity and quantified content…

139 questions
shareeditfollowflag
VV
askedvoid_volume9.5k1510 Feb 2026
5Same situation here, so I will follow this one. – Dr_Bram_Verhoeven 4 months ago
6Can you say which laboratory and which method? The answer changes with both. – jana_horakova 6 months ago
add a comment

5 Answers

Accepted answer first, then by votes
29

Accepted answer

A 98.4 per cent result against a higher certificate figure is usually a method difference, not a disagreement about the vial. Inter-laboratory spread on identical peptide material runs half a per cent to a full per cent by RP-HPLC. Gradient slope, detection wavelength and integration convention each move the number, and a gentler gradient resolves impurities that a steeper one hides under the main peak — so the better method reports the worse figure. Get the column, the gradient and the wavelength from both Janoshik and the supplier before treating 98.4 per cent as a contradiction.

Identity and purity are orthogonal, and a high purity says almost nothing about whether the peak is actually what you think it is.

Integration of the shoulder — whether you use perpendicular drop or tangent skim — determines what area gets assigned to the main peak versus the impurity table.

What each test answers

TestAnswersDoes NOT answer
RP-HPLC, area %What fraction of detected material is the targetHow much target is present
Quantified contentMilligrams of peptide per vialWhat the impurities are
ESI-MS identityWhether the molecular weight matchesPurity, or isomeric substitution
Peptide mappingSequence, localised to a fragmentQuantity
Karl FischerWater content of the solidSolvent content
LAL endotoxinPyrogen load in EU/mgSterility
Sterility testGrowth in defined media over 14 daysEndotoxin, or bioburden count

Concretely, retention time is sequence-specific and method-specific, so comparing your result to a supplier value using a different method is meaningless without method documentation.

The ICH Q3A impurity thresholds and the relevant pharmacopoeial chapters all specify method validation requirements that almost no research-grade certificate claims to meet.

Compare purity within a single laboratory on the same method, never across laboratories.

shareimprove this answerflag
M4
answered · acceptedmz_4113101k35813 May 2026
5I would gently push back on the second point — inter-laboratory spread is wider than stated. – aine_mulcahy 4 months ago
add a comment
Sponsored

Janoshik Analytical - Independent Third-Party Testing

HPLC purity, identity confirmation and quantified content on the vial you actually hold. Reports arrive with the chromatogram attached, not just a number.

Submit a sample
Sponsored — paired listing

GL Biochem (Shanghai) Ltd. - Direct Synthesis

Founded 1998. ISO 9001 and cGMP certified, 1,500+ staff and 200+ patents. The synthesis house behind a great many of the vials that get sent out for testing - batch-specific documentation with every order.

Visit GL Biochem
24

The honest answer is that the achievable range of plausible purity figures for a given vial is wider than most people expect.

Sample solvent strength affects peak shape — if you inject in strong solvent on a gradient starting in weak solvent, the solvent peak can distort your main peak or create a false shoulder.

Mass on column affects detector linearity and peak overlap — overloading broadens peaks and hides neighbours, while underloading improves resolution but loses sensitivity.

Proline conformer interconversion kinetics are well-characterised and the half-life is of the same order as the chromatographic peak width at room temperature.

I would be careful about over-reading a single measurement — treat it as a data point, not as ground truth.

The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.

shareimprove this answerflag
AL
answereda_lindgren58k2482 May 2026
8Two of us submitted the same lot to different laboratories and got results a tenth apart. – k_szabo 43 days ago
7The system-suitability data is the part that tells you whether to believe the rest. – two_two_micron 10 months ago
add a comment
13

In practice, gradient slope is the most powerful parameter and almost nobody mentions it, which is why two reports on the same material disagree by a point.

Temperature affects the dynamics of molecular conformation, and if a peptide has proline residues that interconvert on the chromatographic timescale, the peak will split or shoulder at low temperature and collapse at high temperature.

Concretely, tailing factor measures peak shape, and a badly tailing peak spreads into the region where small impurities live, forcing tangent-skim integration that assigns tail area to the main peak.

The caveat is that purity without identity is only half an answer — a high purity does not mean the peak is actually what you think it is.

If you are ranking vendors, specify a method and have all samples tested at the same place.

shareimprove this answerflag
GS
answeredgradient_slope46k3825 May 2026
2This should be linked from the help pages. – assay_blank 38 days ago
3Which wavelength was the purity integrated at? It changes the number more than people think. – sian_llewellyn 3 months ago
add a comment
10

Put another way, area percentage is not mass percentage, and conflating the two is the most common misreading of a purity figure.

Buffer versus acid in the mobile phase changes the ionisation state of basic and acidic residues, shifting retention and selectivity — same vial, potentially different separation.

Published side-by-side method comparisons show that a two-point difference in purity on the same vial is easily explained by method choice alone.

If you only pay for one test, pay for quantified content. Purity is the number everyone quotes and content is the number that changes what you do.

shareimprove this answerflag
BN
answeredbirk_nordahl16k3819 Mar 2026
8Worth adding that the method section is where the answer usually is. – fibre_or_fragment 3 months ago
7Does this hold for a longer chain length, where the deletion sequences accumulate? – gradient_slope 38 days ago
add a comment
10

In practice, understanding purity requires separating the chemistry from the method from the reporting convention, and the three are not independent.

Detection wavelength matters because 214 nm sees the peptide backbone while 280 nm sees only aromatic side chains — so truncation impurities lacking a tryptophan are invisible at 280 nm.

Inter-laboratory studies on identical peptide material routinely find half-a-per-cent to a full-per-cent spreads in reported purity on the same sample.

In practice: ask for the chromatogram, check the method section, check the lot number against the vial, and set your accept threshold before you see the result rather than after.

edited 29 Jun 2026 by a_lindgren — reworded for clarity after a comment

shareimprove this answerflag
AL
answereda_lindgren58k2485 Jun 2026

Your answer

Ask PeptideStack is a static archive. Posting is closed, but the norms are worth stating: answer the question that was asked, show your working, cite the trial or the certificate, and say plainly where the evidence runs out.

Not medical advice. Research-use-only compounds are not approved for human use.