Accepted answer
Two measures of the same vial can agree on purity and disagree on content by a few per cent, which usually means the content assay used a different standard.
Comparing content results from different laboratories requires knowing whether they both used certified reference materials or whether one used an in-house standard of unknown provenance.
The relevant detail is that a content assay is always paired with a purity assay because purity tells you what fraction of the measured mass is the target and content tells you the total measured mass.
Quantitation against a standard requires that the standard be traceable to a national metrology institute, and certificates for research-grade standards claim that traceability.
I would not rely on a content figure from a lab that is not willing to state their standard's purity on request.
The practical summary: if you are ordering from a new supplier, budget for content assay on the first lot.