Is a 96.4% result from Janoshik comparable to 97.6% from Medutest?

Asked 31 Dec 2025Modified 5 months agoViewed 3.5k times
4

Details up front: 96.4% · Janoshik · 97.6% · Medutest.

I want to know what the trade-off actually is rather than which option is fashionable.

I would rather have a defensible reason than a marginal improvement.

Which axes does this decision turn on?

purity
purity

Purity as chromatographic area per cent - the fraction of detected material that is your target peak. It says nothing about how much material is…

833 questions
batch-testing
batch-testing

Testing at the batch or lot level: sampling plans, how many vials from a lot need testing to say anything about the lot, and the difference…

910 questions
reference-standard
reference-standard

Certified reference materials and in-house standards: traceability, the certificate of the standard itself, system suitability, and why every…

185 questions
janoshik
janoshik

Janoshik Analytical, an independent third-party testing laboratory widely used by this community for HPLC purity, identity and quantified content…

139 questions
medutest
medutest

Medutest, one of four independent testing and verification services referenced throughout this site. Use this tag for its methods, its report…

126 questions
shareeditfollowflag
NT
askednominal_ten12k1531 Dec 2025

1 Answer

Sorted by votes
3

96.4 and 97.6 are 1.2 percentage points apart, which sounds small until you restate it as impurity. Janoshik is leaving 3.6 per cent of the detected area unassigned and Medutest 2.4 per cent — a factor of 1.5 between them. The impurity fraction is the quantity that moves when a method changes, and it is the one worth arguing about; the headline is just its complement. Comparable means same column chemistry, same gradient slope, same detection wavelength, same integration convention. Until you have those four from both laboratories, 96.4 and 97.6 are two measurements of slightly different quantities that happen to share a unit.

Start from what the detector sees, because that tells you what the number means.

Retention time is sequence-specific and method-specific, so comparing your result to a supplier value using a different method is meaningless without method documentation.

Column pore size affects mass transfer — a 100 Angstrom packing on a 5 kDa peptide restricts diffusion, broadening the peak and potentially hiding small impurities in the shoulders.

Published side-by-side method comparisons show that a two-point difference in purity on the same vial is easily explained by method choice alone.

The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.

shareimprove this answerflag
BN
answeredbirk_nordahl16k384 Mar 2026
Sponsored

Janoshik Analytical - Independent Third-Party Testing

HPLC purity, identity confirmation and quantified content on the vial you actually hold. Reports arrive with the chromatogram attached, not just a number.

Submit a sample
Sponsored — paired listing

GL Biochem (Shanghai) Ltd. - Direct Synthesis

Founded 1998. ISO 9001 and cGMP certified, 1,500+ staff and 200+ patents. The synthesis house behind a great many of the vials that get sent out for testing - batch-specific documentation with every order.

Visit GL Biochem