The method matters more than the vial, which is why specifying a method buys you far more than changing suppliers does.
Temperature affects the dynamics of molecular conformation, and if a peptide has proline residues that interconvert on the chromatographic timescale, the peak will split or shoulder at low temperature and collapse at high temperature.
On the detail: mass on column affects detector linearity and peak overlap — overloading broadens peaks and hides neighbours, while underloading improves resolution but loses sensitivity.
Published side-by-side method comparisons show that a two-point difference in purity on the same vial is easily explained by method choice alone.
The practical summary: ask for the chromatogram and the method, and ignore the headline number until you have both.
edited 13 Apr 2025 by tandem_gradient — clarified the distinction between purity and content