Stated carefully, start by separating chemical degradation from physical degradation, because they fail differently and they are detected differently. Chemical degradation changes the molecule and shows up as new peaks on a chromatogram. Physical degradation aggregates the molecule and often shows up as nothing at all on reverse-phase HPLC, because the aggregate never makes it onto the column.
Freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.
The underlying point is that on re-freezing something that thawed in transit: if it arrived as a lyophilised solid that warmed but never got wet, re-freezing costs you nothing except the thermal cycle. If it arrived as a solution that thawed, re-freezing adds a second transition and therefore a second dose of ice-front shear. The asymmetry is worth internalising.
The caveat is that "within specification" and "unchanged" are different claims. A vial can lose a few per cent of content and still be usable for its purpose while no longer matching its certificate.
If the material arrived warm and it was lyophilised, test it and proceed on the result. If it arrived warm and it was in solution, the result is more likely to be interesting than reassuring.