Accepted answer
1.8 percentage points, and the direction is the informative half. VendorInvestigate reports 96.4 per cent and the certificate 98.2, so the independent figure is lower. As impurity that is 3.6 per cent against 1.8 — 2 times as much unassigned area. A gentler gradient resolves impurities that a steeper one hides beneath the main peak, so the better method routinely reports the worse number; 1.8 points is comfortably inside what method choice alone produces on identical material. Ask both parties for the method section before you decide which figure is wrong, because the answer is often neither.
Gradient slope is the most powerful parameter and almost nobody mentions it, which is why two reports on the same material disagree by a point.
Sample solvent strength affects peak shape — if you inject in strong solvent on a gradient starting in weak solvent, the solvent peak can distort your main peak or create a false shoulder.
Mass shifts and what they usually mean
| Δ mass (Da) | Most likely cause | Distinguishing feature |
|---|
| +1 | Deamidation (Asn or Gln) | New peak, slightly earlier retention |
| −17 | Loss of ammonia | Often with deamidation |
| −18 | Dehydration / succinimide | pH-dependent, reversible |
| +16 | Oxidation (Met, Trp) | Earlier retention, light-related |
| −128 | Missing Gln or Lys | Deletion sequence from synthesis |
| 0 | Isomer: racemisation or scrambling | Same mass, shifted retention |
Worth being precise here: detection wavelength matters because 214 nm sees the peptide backbone while 280 nm sees only aromatic side chains — so truncation impurities lacking a tryptophan are invisible at 280 nm.
Proline conformer interconversion kinetics are well-characterised and the half-life is of the same order as the chromatographic peak width at room temperature.
If you are ranking vendors, specify a method and have all samples tested at the same place.