Accepted answer
The part that matters: the lyophilised solid is far more robust than anything anyone says about it, and the solution is far less robust. Most of the confusion in this area comes from advice about one being applied to the other.
Freeze-concentration is the mechanism people miss. As ice forms, everything that is not water is excluded into a shrinking unfrozen fraction, so the local concentration of peptide, buffer salts and preservative rises sharply. If the buffer components crystallise at different rates, local pH can shift by more than a unit. That is why a phosphate-buffered solution can behave badly on freezing while an unbuffered one is fine.
Reported and extrapolated stability by condition
| State | Condition | Usable window | Basis |
|---|
| Lyophilised solid | −20 °C, sealed, dry | 24–36 months | Supplier guidance |
| Lyophilised solid | 2–8 °C, sealed | 12–24 months | Supplier guidance |
| Lyophilised solid | 25 °C, sealed | 4–8 weeks | Extrapolated (Arrhenius) |
| Lyophilised solid | 40 °C, sealed | 1–2 weeks | Extrapolated |
| Solution, preserved | 2–8 °C | 28 days | USP microbiological convention |
| Solution, preserved | 25 °C | 3–7 days | Extrapolated |
| Solution, unpreserved | 2–8 °C | 24 hours | USP microbiological convention |
Windows for the solid state are chemical; windows for solution are microbiological and usually shorter than the chemical limit.
Worth being precise here: adsorption to the container is a real loss at low concentration. For a peptide at 0.1 mg/mL in an untreated glass vial, single-digit percentage losses to the wall are plausible; at 5 mg/mL it is negligible. This is one of several reasons not to reconstitute to a very dilute working solution and store it.
The licensed semaglutide and tirzepatide presentations carry in-use periods of several weeks at room temperature in their labelling, which is the closest thing to real stability data in this space — and it applies to a buffered, surfactant-containing, preservative-containing formulation, not to a reconstituted research vial.
One qualification: none of this addresses sterility. A vial can be chemically pristine and microbiologically compromised, and a chromatogram will not tell you which.
The single highest-value change most people can make is buying a cheap logging thermometer, because it converts an assumption about their storage into a record.