Accepted answer
two weeks is 14 days, and at 40 °C the ten-degree rule of thumb makes that roughly 158 refrigerated days of equivalent exposure. 40 °C is 35 kelvin above the 5 °C middle of a 2–8 °C refrigerator. The ten-degree rule of thumb — degradation rate roughly doubling per 10 K — makes that about 11 times the refrigerated rate, which is an order-of-magnitude statement and not a shelf life. Compare that against what the certificate covers, which is the material as it left the laboratory on the date of analysis and nothing after it. That is short enough that a re-test is a stability study rather than a safety check — worth doing if you will publish the result, hard to justify if you will only reassure yourself. If you do re-test, send it for content as well as purity; the 14 days will have moved one of them further than the other.
Thermal history during shipping is different for every vial, so a lot that experienced thermal abuse may have internal variation even if it was originally homogeneous.
Under AQL sampling plans, testing two vials from a fifty-vial lot gives you an operating characteristic curve that tells you what risks you are accepting.
Put another way, for a quantitative result like content, the acceptable range determines how many vials you need to test to establish the lot complies.
Published data on lot homogeneity from manufacturers who sample multiple vials consistently find variation below the published specifications, suggesting the sampling plans work.
The limitation is that you cannot know for certain without testing every vial, and you almost never can afford to do that.
Assume segregation is possible, and design your sampling to catch it if it exists.
5Small correction: the limit of quantitation, not the limit of detection, is the relevant one there. – h_villanueva 6 months ago add a comment