96.4 per cent purity with no content figure leaves the milligram number unmeasured. Purity says 96.4 of every 100 units of detected area is cagrilintide and 3.6 is something else. Content says how many milligrams are in the glass. The two do not constrain each other: a vial can be 96.4 per cent pure and still be under label, because water and counter-ion are part of the gross mass and neither shows up as an impurity peak. If you buy one test, buy the one that changes your arithmetic.
Gradient slope is the most powerful parameter and almost nobody mentions it, which is why two reports on the same material disagree by a point.
Sample solvent strength affects peak shape — if you inject in strong solvent on a gradient starting in weak solvent, the solvent peak can distort your main peak or create a false shoulder.
Mechanically, buffer versus acid in the mobile phase changes the ionisation state of basic and acidic residues, shifting retention and selectivity — same vial, potentially different separation.
The Arrhenius relationship for peptide degradation is the basis of accelerated stability testing and also governs how quickly methods drift with temperature.
Compare purity within a single laboratory on the same method, never across laboratories.
edited 28 Jul 2026 by ivo_paunovic — updated for the 2026 guidance change
6Confirming from the other direction: I ignored the method section once and paid for it. – Dr_Idris_Coulibaly 37 days ago 5The distinction between purity and content cannot be repeated often enough here. – Dr_Ilse_Vandenberg 9 months ago add a comment