Accepted answer
10 mg/mL, so one unit carries 0.1 mg. 5 ÷ 0.5 = 10 mg/mL; one unit on a U-100 barrel is 0.01 mL; 10 × 0.01 = 0.1 mg per unit. To go the other way, divide your intended dose by 0.1: a 1 mg dose is 10 units, and a 2 mg dose is 20. Write both the concentration and the milligrams per unit on the vial.
This is arithmetic, so let us do the arithmetic rather than argue about it.
Breaking it down further: if a 10 mg vial has 96.5 per cent content, you have 9.65 mg of peptide. Divide that by 2.00 mL and your concentration is 4.825 mg/mL, not 5.00 mg/mL, which is a 3.5 per cent systematic error in every dose calculation.
The rounding error accumulates if you round too many times — rounding concentration to 5.0, rounding the dose volume to 0.1 mL, rounding the unit reading to 10 — and the safest approach is to work the full precision and round only the final answer.
Published data on syringe dead space quantifies low-dead-space designs as retaining under 2 µL against 35 µL or more for conventional detachable-needle syringes.
Do the arithmetic twice, ideally with someone else doing it independently.
7Adding a vote because this deserves more of them. – lucia_marchetti 33 days ago 8Does this change at lower concentrations, or does adsorption start to dominate? – tabular_nums 3 months ago add a comment